7.5.7.3.3
Parameters
tab
The
Parameters
tab is used to enter the set values for the screw check.
Figure 73: ROI Screw, Parameters tab
Function
Description
1
Screw diameter.
2
Hole diameter.
3
Nominal height that the screw protrudes above the surrounding region.
4
Height tolerance (in mm), which specifies how far down (screw protrudes less)
the area can be before the test is output as NOK.
5
Height tolerance (in mm), which specifies how far up (screw protrudes further)
the area can be before the test is output as NOK.
6
Calculated value (in mm) of the screw height.
Example
A nominal height of 6 mm is required to have a tolerance of 1 mm at the bottom and
3 mm at the top.
Screw Height Lower Tolerance
(
4
) should then be set to
1
mm and
Screw
Height Upper Tolerance
(
5
) to
3
mm.
7.5.7.3.4
ROI
tab
The region can be positioned graphically or using the configuration options in the
window shown below.
Figure 74: ROI Screw, Parameters tab
OPERATION
7
8027445/V1-0/2022-06-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | FOS-HVS
71
Subject to change without notice