Reference images
The reference image is required for setting up the inspections. It is recommended to
take an image of an OK part as a reference image. This makes it easier to set the target
values and the tolerances (e.g., for screw inspection).
7.5.4.2.1
Preprocessing
tab
The
Preprocessing
tab is used to configure the settings for image preprocessing.
Figure 35: Camera menu page, Preprocessing
Function
Description
1
This option supports system maintenance and further development.
NOTE
This option is not required in check mode. Since this option uses up
additional time, it should always be deactivated in inspection mode.
2
The Median filter is used for image preprocessing. This parameter must not be
changed.
The filter size can be changed using the – and + buttons. The default setting is
filter size 2
3
Image preprocessing is used to improve the evaluability of the camera image.
4
Calibrate camera image.
5
Perform image preprocessing and calibration in one sequence.
7.5.4.2.2
3D Image Settings
tab
The
3D Image Settings
tab is used to configure the 3D settings for the heightmap and
height range.
Figure 36: Camera menu page, 3D Image Settings
7
OPERATION
42
O P E R A T I N G I N S T R U C T I O N S | FOS-HVS
8027445/V1-0/2022-06-15 | SICK
Subject to change without notice