13.3
Control bits process diagram
False
False
False
True
True
True
ControlBitsOut
2
3
False
True
1
True
True
True
ControlBitsIN
2
3
4
False
True
1
False
True
True
5
False
False
False
False
False
True
False
True
False
True
6
7
8
9
False
True
16
InspectionStart
SafetyViolation
ArticleValid
ReadyToInspect
ResultOK
ResultNOK
BVReady
ResultInvalid
SurfaceOK
SurfaceNOK
ScrewOK
ScrewNOK
FTPError
St
a
rt
syst
e
m
Art
icl
e
su
b
mi
ssi
o
n
Mo
ve
p
o
rt
a
l
sh
o
rt
ly
a
ft
e
r
st
a
rt
o
f
in
sp
e
ct
io
n
Ej
e
ct
H
VS
o
r
re
p
e
a
t
in
sp
e
ct
io
n
R
e
su
lt
su
b
m
issi
o
n
Im
a
g
e
a
cq
u
isi
ti
o
n
/
p
ro
ce
ssi
n
g
L
o
a
d
a
rt
icl
e
In
it
ia
liza
ti
o
n
13.4
Control bits IN
Name
Control bit
BVReady
1
ReadyToInspect
2
ResultOK
3
ResultNOK
4
ResultInvalid
5
SurfaceOK
6
SurfaceNOK
7
ScrewOK
8
ScrewNOK
9
- free -
10
- free -
11
- free -
12
- free -
13
- free -
14
- free -
15
FTPError
16
13.5
Control bits OUT
Name
Control bit
ArticleValid
1
ANNEX
13
8027445/V1-0/2022-06-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | FOS-HVS
99
Subject to change without notice