85
TROUBLESHOOTING
7
Information appearing in the TYPE/NOTE column
Information such as the type of transmission and type of error appears in the TYPE/NOTE column of the Transaction
Report. The following notes may appear.
Note
Explanation
OK
The transaction was completed normally.
G3
Communication took place in G3 mode.
ECM
Communication took place in G3 ECM mode.
SG3
Communication took place in Super G3 mode.
FW.
The received data was forwarded.
NO RESPONSE
No response from the receiving party.
BUSY
Transmission was not possible because the other party was already using the
line.
CANCEL
A transmission was cancelled while in progress, or a stored transmission job
was cancelled.
P. FAIL
A power failure occurred during the transaction.
MEMORY. FULL
The memory became full during reception.
LENGTH OVER
The transmitted document was over 59" long and therefore could not be
received.
ORIG ERROR
Manual transmission was not successful because a jam occurred.
PASSCODE# E
The connection was broken because the polling passcode was not correct.
RX NO POLL
The machine that was polled does not have a polling function.
NO RX POLL
The other machine refused the polling operation, or your machine broke the
connection when polled because no data was in polling memory.
SA POL TX ERR
The other machine refused an F-code polling operation.
SA POLL ERR
Your machine broke the connection because the other machine specified an
F-code polling sub-address that does not exist in your machine.
NO SA POLLING
F-code polling was attempted, however, the other machine did not have an
F-code polling memory box.
NO S ADD FUNC
F-code transmission was attempted, however, the other machine does not
support F-code communication.
S ADD TX FAIL
An F-code transmission was refused by the other machine because of an
incorrect sub-address or other reason.
ERROR xx xxxx
The communication handshake signals or image signals were distorted due to
line conditions or other reasons, and communication was not successful.
Codes for use by service technicians. For more infomation, consult your
authorised service representative.