5
Electrical installation
Assignment of the optional plug connectors
Operating Instructions – MOVIMOT
®
flexible
95
5.11.2
X5504: STO (3 cores)
WARNING
No safe disconnection of the device.
Severe or fatal injuries.
•
Do not use the 24 V output (pins 1 and 3) for safety-related applications.
•
Only jumper the STO connection with 24 V if the device does not have to fulfill
any safety function.
The following table shows information about this connection:
Function
Connection for safe torque off (STO, 3 cores)
Connection type
M12, 5‑pin, female, A‑coded, color: yellow
Connection diagram
1
4
3
2
5
Assignment
Contact
Signal
Description
1
24V_OUT
DC 24 V auxiliary output
2
F_STO_P2
F_STO_P2 connection
3
0V24_OUT
0V24 reference potential for DC 24 V auxiliary output
4
F_STO_P1
F_STO_P1 connection
5
F_STO_M
F_STO_M connection
29128668/EN – 12/2019