6
Startup
Startup notes
Operating Instructions – MOVIMOT
®
flexible
158
WARNING
Risk from falling loads.
This can result in severe or fatal injuries.
•
Do
not
use the function "Releasing the brake / deactivating DynaStop
®
with
FCB 01" for hoist applications and applications with potentially falling loads.
•
Inhibit the function via the following steps:
– Deactivate the function of the DIP switch S1/2 using the parameter
Deactiva-
tion
=
"1"
(path:
Functions
>
Inputs/outputs
>
Basic device
>
DIP switch func-
tions
>
Releasing the brake / deactivating DynaStop
®
with FCB 01 – enable
)
– Inhibit the functions using the parameter
Releasing the brake / deactivating
DynaStop
®
with FCB 01 – enable
=
"0"
(path:
Functions
>
Drive functions
>
FCB 01 Output stage inhibit
).
INFORMATION
The recommended settings and procedures must be matched to the requirements of
the application and its safety assessment, and adjusted accordingly.
SEW‑EURODRIVE recommends the following settings and procedures for lifting ap-
plications:
•
Set parameter
Apply brake/activate DynaStop
®
in STO state (8501.3)
= "1"
(Yes),
see chapter "DynaStop
®
in conjunction with STO".
•
Set parameter
Integrator mode (8404.9)
=
"0"
(hold).
Path:
Optimization DT1 > Set controller dynamics > Advanced settings
.