Subfault: 18.9
Description: Internal software error
Response: Output stage inhibit
System state: Fault acknowledgement with CPU reset
Cause
Measure
The software signals an unexpected event.
– Switch the device off and on again.
– If the error occurs repeatedly, replace the
device and send it together with the error number
to SEW-EURODRIVE. For further support, con-
tact SEW-EURODRIVE Service.
Subfault: 18.10
Description: Watchdog
Response: Output stage inhibit
Cause
Measure
Software no longer operates within intended cycle
time.
– Switch the device off and on again.
– Contact the SEW‑EURODRIVE Service if the
error persists.
Subfault: 18.12
Description: Configuration data
Response: Output stage inhibit
System state: Fault acknowledgement with CPU reset
Cause
Measure
Configuration data not plausible or cannot be in-
terpreted by active firmware version.
Perform a firmware update or load valid configur-
ation data.
Subfault: 18.13
Description: Calibration data
Response: Output stage inhibit
System state: Fault acknowledgement with CPU reset
Cause
Measure
Calibration data not plausible.
Load valid calibration data.
8.6.15
Fault 19 Process data
Subfault: 19.1
Description: Torque setpoint violation
Response: Application stop + output stage inhibit
Cause
Measure
Implausible values specified as torque setpoints.
Adjust torque setpoints.