6
Startup
Detailed motor selection table for startup via DIP switch S3
Operating Instructions – MOVIMOT
®
flexible
171
6.4.3
MOVIGEAR
®
classic motor series
Motor series
Motor protection
DIP switch S3
Temperature sensor
DIP switch S3
S3/7
S3/8
S3/9
S3/10
S3/5
S3/6
0
1
1
0
No temperature sensor
0
0
PK (PT1000)
1
0
TF
1)
0
1
TH
1)
1
1
1) MOVIGEAR
®
classic is available only with PK temperature sensor (PT1000).
The following table shows the settings of the DIP switch S3 depending on the motor
and the nominal output current of the inverter.
Motor
Electronics cover
DIP switch S3
Motor type
Brake
Type des-
ignation
Nominal out-
put current
Connec-
tion type
Motor assignment in rela-
tion to the inverter power
Type/nom-
inal voltage
S3/1
1)
S3/2
2)
S3/3 S3/4
Motor power
MGF..-1-..C
–
0
0020
2.0 A
W
0
0
0
Adjusted
0025
2.5 A
1
0
1 stage smaller
0032
3.2 A
0
1
2 stages smaller
0040
4.0 A
1
1
3 stages smaller
0055
5.5 A
MGF..-2-..C
–
0
0020
2.0 A
W
0
0025
2.5 A
0
0
Adjusted
0032
3.2 A
0
0
Adjusted
0040
4.0 A
1
0
1 stage smaller
0055
5.5 A
0
1
2 stages smaller
MGF..-4-..C
–
0
0020
2.0 A
W
0
0025
2.5 A
0032
3.2 A
0040
4.0 A
0
0
Adjusted
0055
5.5 A
1
0
1 stage smaller
MGF..-4-..C/
XT
–
0
0020
2.0 A
W
0
0025
2.5 A
0032
3.2 A
0040
4.0 A
0055
5.5 A
0
0
Adjusted
The motor cannot be started up using DIP switch S3. MOVISUITE
®
or CBG.. is required for
startup.
1) MOVIGEAR
®
classic is not available with brake. DIP switch S3/1 is ignored.
2) MOVIGEAR
®
classic is available only with star connection. DIP switch S3/2 must be set to 0 = STAR.