7
Operation
Switch disconnector
Operating Instructions – MOVIMOT
®
flexible
182
7
Operation
7.1
Switch disconnector
WARNING
Electric shock due to dangerous voltages at the line terminals.
The switch disconnector disconnects the electronics cover from the voltage supply.
Voltage is still present at the terminals of the device.
•
A correct installation includes that terminals of the device are protected against
contact.
•
Secure the device against unintended reconnection of the voltage supply.
•
Wait for at least the following time before removing the electronics cover:
5 minutes
NOTICE
Increased wear of the switch contacts.
Destruction of the switch contacts.
•
Do not operate the switch disconnector under load.
The switch disconnector of the device serves to interrupt the voltage supply of the
electronics cover. The feedback contact (NC contact) of the switch disconnector af-
fects the digital input DI08 of the device. If the device is connected to a DC 24 V
backup voltage, the status of the switch disconnector can be retrieved via digital input
DI08.
The switch disconnector can be secured with 3 locks.
Ø 5 – Ø 8 mm
26585544715
29128668/EN – 12/2019
Содержание MOVIMOT flexible MMF3 C/DBC Series
Страница 2: ...SEW EURODRIVE Driving the world ...
Страница 429: ......
Страница 430: ......
Страница 431: ......