8
Service
Fault table standard
Operating Instructions – MOVIMOT
®
flexible
221
Subfault: 13.10
Description: Position tolerance range monitoring
Response: Encoder 1 – latest critical fault
Cause
Measure
Position outside tolerance range.
– Check startup parameters.
– Check the wiring.
– Check interference sources (light beam inter-
rupted, reflector, data cables, etc.).
– Replace the encoder.
Note: In "emergency mode" manual mode, you
can move the drive using the motor encoder if the
external position encoder is faulty.
Subfault: 13.11
Description: Data timeout
Response: Encoder 1 – latest critical fault
Cause
Measure
Encoder process data timeout.
– Check interference sources (e.g. from EMC).
– Check startup parameters.
Note: In "emergency mode" manual mode, you
can move the drive using the motor encoder if the
external position encoder is faulty.
Subfault: 13.12
Description: Emergency
Response: Encoder 1 – latest critical fault
Cause
Measure
Encoder signaled emergency.
– Check interference sources (e.g. from EMC).
– Check startup parameters.
Note: In "emergency mode" manual mode, you
can move the drive using the motor encoder if the
external position encoder is faulty.