Subfault: 13.20
Description: SSI error bit – critical
Response: Encoder 1 – latest critical fault
Cause
Measure
Error bit set in SSI protocol.
– Check the startup parameters.
– Check the settings at the SSI encoder (fault bit).
– Check the wiring.
– Check interference sources (light beam inter-
rupted, reflector, data cables, etc.).
– Replace the encoder.
Information: In "emergency mode" manual mode,
you can move the drive even with a fault in an ex-
ternal position encoder.
Subfault: 13.21
Description: SSI error bit
Response: Encoder 1 – latest fault
Cause
Measure
Error bit set in SSI protocol.
– Check the startup parameters.
– Check the settings at the SSI encoder (fault bit).
– Check the wiring.
– Check interference sources (light beam inter-
rupted, reflector, data cables, etc.).
– Replace the encoder.
Information: In "emergency mode" manual mode,
you can move the drive even with a fault in an ex-
ternal position encoder.
Subfault: 13.22
Description: Internal fault – critical
Response: Encoder 1 – latest critical fault
Cause
Measure
Encoder signaled internal fault.
– Check the wiring.
– Check interference sources (light beam inter-
rupted, reflector, data cables, etc.).
– Replace the encoder.
Information: In "emergency mode" manual mode,
you can move the drive using the motor encoder
even if the external position encoder is faulty.