8
Service
Fault table standard
Operating Instructions – MOVIMOT
®
flexible
225
Subfault: 13.23
Description: Internal fault
Response: Encoder 1 – latest fault
Cause
Measure
Encoder signaled internal fault.
– Check the wiring.
– Check interference sources (light beam inter-
rupted, reflector, data cables, etc.).
– Replace the encoder.
Note: In "emergency mode" manual mode, you
can move the drive using the motor encoder if the
external position encoder is faulty.
Subfault: 13.24
Description: Travel range exceeded
Response: Encoder 1 – latest fault
Cause
Measure
Current position mode (index 8381.10) does not
allow for larger travel range.
Check the travel range.
Note: In "emergency mode" manual mode, you
can move the drive using the motor encoder if the
external position encoder is faulty.
Subfault: 13.25
Description: Error during encoder startup
Response: Output stage inhibit
Cause
Measure
Fatal error during encoder startup.
Switch the device off and on again.
Note: In "emergency mode" manual mode, you
can move the drive using the motor encoder if the
external position encoder is faulty.
Subfault: 13.26
Description: Digital motor integration fault – critical
Response: Encoder 1 – latest critical fault
Cause
Measure
Encoder of "digital motor integration" signaled a
component fault.
– Check interference sources.
– Replace the encoder.
Subfault: 13.27
Description: Digital motor integration fault
Response: Encoder 1 – latest fault
Cause
Measure
Encoder of "digital motor integration" signaled a
component fault.
– Check interference sources.
– Replace the encoder.
29128668/EN – 12/2019
Содержание MOVIMOT flexible MMF3 C/DBC Series
Страница 2: ...SEW EURODRIVE Driving the world ...
Страница 429: ......
Страница 430: ......
Страница 431: ......