5
Electrical installation
Installation instructions
Operating Instructions – MOVIMOT
®
flexible
50
5.3.3
Permitted cable cross section of terminals
Line terminals X1
Observe the permitted cable cross sections for installation:
Line terminals X1
Without conductor end
sleeve
With conductor end
sleeve
(with or without plastic
collar)
Connection cross sec-
tion (mm
2
)
0.5 mm
2
– 6 mm
2
0.5 mm
2
– 6 mm
2
Stripping length
13 mm – 15 mm
Terminals X2_A for motor, brake and temperature sensor
Observe the permitted cable cross sections for installation:
Terminals X2_A
for motor, brake and
temperature sensor
Without
conductor end
sleeve
With
conductor end
sleeve (without
plastic collar)
With
conductor end
sleeves (with
plastic collar)
Connection cross sec-
tion
0.08 mm
2
–
2.5 mm
2
0.08 mm
2
–
1.5 mm
2
0.08 mm
2
–
1.5 mm
2
Stripping length
8 mm – 9 mm
Terminals X3 for braking resistor
Observe the permitted cable cross sections for installation:
Terminals X3 for braking
resistor
Without conductor end
sleeve
With conductor end
sleeve
(with or without plastic
collar)
Connection cross sec-
tion
0.08 mm
2
– 4.0 mm
2
0.25 mm
2
– 2.5 mm
2
Stripping length
8 mm – 9 mm
Control terminals X9
Observe the permitted cable cross sections for installation:
Control terminals X9
Without
conductor end
sleeve
With
conductor end
sleeve (without
plastic collar)
With
conductor end
sleeves (with
plastic collar)
Connection cross sec-
tion
0.08 mm
2
–
2.5 mm
2
0.25 mm
2
–
2.5 mm
2
0.25 mm
2
–
1.5 mm
2
Stripping length
5 mm – 6 mm