6
Startup
Configuring the drive behavior at standstill (FCB02, FCB13, FCB14)
Operating Instructions – MOVIMOT
®
flexible
181
6.9
Configuring the drive behavior at standstill (FCB02, FCB13, FCB14)
The parameter
Behavior at standstill
defines the drive behavior in case the drive en-
able is revoked and the motor is at standstill (path:
Functions
>
Drive functions
>
FCB 02 Stop default
). This parameter is effective when the function blocks FCB 02,
FCB 13 and FCB 14 are active.
The following table lists the drive behavior after motor standstill:
Index
Parameters
Setting
Behavior at motor standstill
Brake/
DynaStop
®
Motoring
position hold
control
Effect on the
the motor shaft
8563.1
Behavior at standstill
(Path:
Functions >
Drive functions >
FCB02 Stop default
)
Drive energized (brake
released / DynaStop
®
deactivated)
Brake re-
leased
Position hold
control
active
The motor shaft is
regulated to rota-
tional speed = "0"
by the motor.
DynaStop
®
is deactiva-
ted
Drive not energized
(brake applied /
DynaStop
®
activated)
Brake
applied
Motor de-ener-
gized
Motor shaft is held
by brake.
DynaStop
®
is activated
The motion of the
motor shaft is re-
tarded by
DynaStop
®
.
Drive not energized
(without brake/
DynaStop
®
)
Brake re-
leased
Motor de-ener-
gized
The motor shaft
can rotate freely.
DynaStop
®
is deactiva-
ted
29128668/EN – 12/2019