6
Startup
Startup notes
Operating Instructions – MOVIMOT
®
flexible
157
NOTICE
Undercutting the minimum switch-off time of the line contactor.
Irreparable damage to the inverter or unforeseen malfunctions.
•
You must observe a minimum switch-off time of 10 s after switching off the
voltage supply.
•
Do not switch the voltage supply on or off
more often than once per minute
.
INFORMATION
•
Before startup, remove the paint protection cap from the LED displays.
•
Before startup, remove the paint protection film from the nameplates.
INFORMATION
•
To ensure fault-free operation, do not disconnect or connect signal cables during
operation.
6.1.1
Lifting applications
WARNING
Danger of fatal injury if the hoist falls.
Severe or fatal injuries.
•
In case of products used in lifting applications, additional monitoring systems or
mechanical protection devices must be used.
NOTICE
Application in ELSM
®
control mode
When the inverter is operated in ELSM
®
control mode, using it in lifting applications
is not permitted. In this control mode only applications of horizontal materials hand-
ling are permitted.
Startup notes for lifting applications
WARNING
The DynaStop
®
electrodynamic retarding function does not allow for a definite stop
at a position.
This can result in severe or fatal injuries.
•
DynaStop
®
must not be used for hoists.
•
When DynaStop
®
is used on inclining/downward slopes or for vertical conveyors
without free hanging loads, adhere to the basic safety and health requirements
(e.g. the EG Machinery Directive 2006/42/EG).
•
The behavior of the DynaStop
®
function must be taken into account for the risk
assessment of the application, that determines the required safety measures.
29128668/EN – 12/2019
Содержание MOVIMOT flexible MMF3 C/DBC Series
Страница 2: ...SEW EURODRIVE Driving the world ...
Страница 429: ......
Страница 430: ......
Страница 431: ......