5
Electrical installation
Assignment of the optional plug connectors
Operating Instructions – MOVIMOT
®
flexible
111
Connection of cables with open end
The following table shows the conductor assignment of cables with the following part
number:
Part numbers
28117751
Assembly
Open cable end
Description
Prefabricated plug
connectors
1
4
2
3
Core
color/
Core
cross sec-
tion
Identi-
fication
Assembly
Signal
Contact
Black
2.5 mm
2
1
Not pre-
fabricated
DC 24 V output/L1
(for backup voltage/supply)
+24V/L1
1
Black
2.5 mm
2
2
Not pre-
fabricated
0V24 reference potential/N2
(for DC 24 V /BES brake rectifier)
0V24/N2
2
Black
2.5 mm
2
3
Not pre-
fabricated
0V24 reference potential/N1
(for backup voltage/supply)
0V24/N1
3
Black
2.5 mm
2
4
Not pre-
fabricated
DC 24 V output/L2
(for DC 24 V /BES brake rectifier)
+24V/L2
4
Black
2.5 mm
2
5
Not pre-
fabricated
Functional earth
FE
29128668/EN – 12/2019