8
Service
Fault table standard
Operating Instructions – MOVIMOT
®
flexible
263
Subfault: 46.50
Description: Warning
Response: Warning with self reset
Cause
Measure
Safety card signals subcomponent fault of the
type "warning".
For the exact cause of the fault and for informa-
tion on how to correct the cause of the problem,
refer to the fault reported by the subcomponent
(index 8365.3).
Subfault: 46.51
Description: Fault
Response: Emergency stop + output stage inhibit with self reset
Cause
Measure
Safety card signals subcomponent fault of the
type "standard fault".
For the exact cause of the fault and for informa-
tion on how to correct the cause of the problem,
refer to the fault reported by the subcomponent
(index 8365.3).
Subfault: 46.52
Description: Critical fault
Response: Output stage inhibit with self reset
Cause
Measure
Safety card signals subcomponent fault of the
type "critical fault".
– For the exact cause of the fault and for informa-
tion on how to correct the cause of the problem,
refer to the fault reported by the subcomponent
(index 8365.3).
– If the jumper plug is plugged at terminal "X6",
remove the jumper plug.
8.6.33
Fault 48 Module bus
Subfault: 48.2
Description: Timeout
Response: Emergency stop + output stage inhibit
Cause
Measure
Timeout detected by module bus.
Check cable connections and voltage supply of
module bus stations.
8.6.34
Fault 51 Analog processing
Subfault: 51.1
Description: Analog current input 4 mA limit
Response: Warning with self reset
Cause
Measure
Input current below 4 mA.
Check input current.
29128668/EN – 12/2019
Содержание MOVIMOT flexible MMF3 C/DBC Series
Страница 2: ...SEW EURODRIVE Driving the world ...
Страница 429: ......
Страница 430: ......
Страница 431: ......