Subfault: 18.4
Description: Task system
Response: Output stage inhibit
System state: Fault acknowledgment with CPU reset
Cause
Measure
Error while processing internal task system. This
may be a timeout for cyclical tasks, for example.
– Switch the device off and on again.
– Contact SEW‑EURODRIVE Service if the error
persists.
Subfault: 18.7
Description: Fatal error
Response: Output stage inhibit
System state: Fault acknowledgment with CPU reset
Cause
Measure
Fatal software error.
– Switch the device off and on again.
– If the error occurs repeatedly, replace the
device and send it together with the fault number
to SEW-EURODRIVE. For further support, con-
tact SEW-EURODRIVE Service.
Subfault: 18.8
Description: Invalid fault code
Response: Output stage inhibit
Cause
Measure
Invalid fault code requested.
– Switch the device off and on again.
– Contact SEW‑EURODRIVE Service if the fault
persists.
Subfault: 18.9
Description: Internal software error
Response: Output stage inhibit
System state: Fault acknowledgment with CPU reset
Cause
Measure
The software reports an unexpected event.
– Switch the device off and on again.
– If the error occurs repeatedly, replace the
device and send it together with the fault number
to SEW-EURODRIVE. For further support, con-
tact SEW-EURODRIVE Service.