2-6
SPEC
E
MAINTENANCE SPECIFICATIONS
LOWER
ELECTRICAL
Item
Unit
Model
Moray 25 M Moray 25 E
GEAR BACKLASH
Pinion - forward
mm (in)
0.31 ~ 0.72 (0.012 ~ 0.028)
Mid-point
mm (in)
0.51 (0.020)
Pinion - reverse
mm (in)
0.93 ~ 1.65 (0.037 ~ 0.065)
Mid-point
mm (in)
1.29 (0.051)
Pinion shim
mm
0.7, 1.0, 1.1, 1.2, 1.3, 1.4, 1.5, 1.6
Forward shim
mm
1.0, 1.1, 1.2, 1.3, 1.4
Reverse shim
mm
1.0, 1.1, 1.2, 1.3
Item Unit
Model
Moray 25 M Moray 25 E
IGNITION SYSTEM
Ignition timing
Degree (BTDC)
10 ~ 30
±
3
Charge coil output peak voltage
(G/W – W/G)
@ cranking 1*
V
210
@ cranking 2*
V
240
@1,500 r/min
V
210
@3,500 r/min
V
210
Pulser coil output peak voltage
(R – W)
@ cranking 1*
V
90
@ cranking 2*
V
90
@1,500 r/min
V
210
@3,500 r/min
V
240
CDI unit output peak voltage
(B/W – O)
@ cranking 1*
V
180
@ cranking 2*
V
200
@1,500 r/min
V
190
@3,500 r/min
V
190
Spark plug gap
mm (in)
0.9 ~ 1.0 (0.035 ~ 0.039)
Charge coil resistance
(W/G – G/W)
Ω
660 ~ 710
Pulser coil resistance
Ω
300 ~ 350
Ignition coil resistance
Primary
Ω
0.08 ~ 0.70
Secondary
k
Ω
3.5 ~ 4.7
* Cranking 1: Open circuit
Cranking 2: Related parts are connected.