8-19
–
+
ELEC
E
STARTING SYSTEM
BATTERY
Refer to “GENERAL” in chapter 3.
FUSE
1. Check:
●
Fuse holder
No continuity
→
Check the fuse
holder leads.
●
Fuse holder leads
No continuity
→
Replace the fuse
holder.
Continuity
→
Check the fuse.
2. Check:
●
Fuse
No continuity
→
Replace.
Fuse rating:
12 V - 20 A
WIRE HARNESS
1. Check:
●
Continuity
No continuity
→
Replace.
WIRE CONNECTIONS
1. Check:
●
Wire connections
Poor connections
→
Properly con-
nect.
STARTER RELAY
1. Check:
●
Starter relay condition
Out of specification
→
Replace.
Checking steps:
●
Connect the tester between the starter
relay terminals as shown.
Tester positive lead
1
→
Starter relay terminal
Tester negative lead
2
→
Starter relay terminal
●
Check that there is no continuity
between the starter relay terminals.
●
Connect the tester and battery
between the starter relay terminals.
2
4
3
1