PROFIBUS-DP Modules
132
Operating Manual XCx 300 / 500 / 540 Version 09/08
13.5
Displays and Connections XF-DPS
Display
LED Des.
Colour
Condition
Description
XF-DPS
L1
L2
L3
L4
X51
L1
BF
red
No bus connection (bus fail)
Field bus cable break or the master does not operate the
bus (any more).
green
Bus connection active
yellow
flashing
Bus connection active,
however no data exchange.
L2
DIA
yellow
flashing
Static diagnosis active
L3
SYS
yellow
flicking
Hardware error
green
flashing
Ready connecting to bus, however no (not as yet) bus
connection active.
green
flicking
Bus connection error
green
Bus connection active
L4
COM
yellow
Cyclic data exchange active
Connector X51
Pin
Designation
1
nc
not connected
2
nc
not connected
3
RxD/TxD-P Receive/Transmit Data P
4
CNTR-P
Repeater Control Signal
5
DGND
Data Ground (0 V)
6
VP
Voltage Plus (+5 V)
7
nc
not connected
8
RxD/TxD-N Receive/Transmit Data N
9
nc
not connected
13.6
Technical Data XF-DPS
Basic data
Interface
PROFIBUS-DP Slave
Data transmission rate
up to 12 MBaud
Connection system
Subminiature type D, 9-pin, socket connector
Ambient temperature working range
0°C to 45°C