Error messages
Operating Manual XCx 300 / 500 / 540 Version 09/08
155
14.3.7
0x0220 Axis errors
The axis number is indicated in the parameter.
Error no.
Error text
Cause / Remedy
0x02200000 Messkreisfehler
(Achse n)
[Measuring circuit error
(Axis n)]
Cyclical data exchange between the PN-MIC
xx and the drive has been interrupted.
0x02200001 Stillstandsüberwachung
(Achse n)
[Zero-speed control
(Axis n)]
An axis has left the zero-speed control
window Q.046 without a travel assignment or
did not reach the set control window quickly
enough. The control deletes the controller
enable after the delay time Q.047 (ms).
Possible causes:
Control time too short (Q.047)
Control window too small (Q.046)
Controller amplification factor too small
Drift compensation set incorrectly
0x02200002 Schleppabstand zu groß
(Achse n)
[Following error too large
(Axis n)]
The drive cannot follow the values set in the
CNC.
Following error control causes feed stop with
ramp.
Possible cause:
Either the maximum velocity Q.023 is too
large,
the maximum following error Q.042 too small,
the KV factor Q.022 too small or
the drive defective.
0x02200003 Reglerfreigabe fehlt
(Achse n)
[no controller enable
(Axis n)]
The position controller was opened from the
outside by taking away the controller enable
while the axis was moving.
0x02200004 Softwareendsc
(Achse n)
[Software limit
(Axis n)]
The boundary set in Q.035 has been reached
(only effective after homing).
0x02200005 Softwareendschalter -
(Achse n)
[Software limit switch -
(Axis n)]
The boundary set in Q.036 has been reached
(only effective after homing).
0x02200006 Vorschubfreigabe fehlt
(Achse n)
[No feed enable
(Axis n)]
The travel assignment of an axis cannot be
executed due to a missing feed enable (PLC
program).
0x02200007 Hardwareendsc
(Achse n)
[Hardware limit
(Axis n)]
The axis is on the + hardware limit switch.
It can be moved manually in "-" direction.
0x02200008 Hardwareendschalter -
(Achse n)
[Hardware limit switch -
(Axis n)]
The axis is on the - hardware limit switch.
It can be moved manually in "+" direction.