Error messages
Operating Manual XCx 300 / 500 / 540 Version 09/08
169
-10
NC-Speicherfehler:
Falsche NC-Programmnummer
[NC memory error:
Incorrect NC program number]
Selected program number for
deleting is incorrect
-11
NC-Speicherfehler:
Das NC-Programm ist aktiv
[NC memory error:
The NC program is active]
An active program cannot be
deleted or overwritten
-12
Falsche Anfangskennung
(Q- oder R-Parameter-Datei) (Zeile n)
[Incorrect start identifier
(Q or R parameter file) (Line n)]
An error has occurred in line <n>
due to an incorrect start identifier.
-13
Falsche Parameternummer
(Q- oder R-Parameter-Datei) (Zeile n)
[Incorrect parameter number
(Q or R parameter file) (Line n)]
An error has occurred in line <n>
due to an incorrect parameter
number.
-14
Falscher Parameterwert
(Q- oder R-Parameter-Datei) (Zeile n)
[Incorrect parameter value
(Q or R parameter file) (Line n)]
An error has occurred in line <n>
due to an incorrect parameter value.
-15
Parameter nicht vorhanden
(Q- oder R-Parameter-Datei) (Zeile n)
[Parameter does not exist
(Q or R parameter file) (Line n)]
An error has occurred in line <n>.
The parameter does not exist.
-16
Falsche Systemnummer
(Q- oder R-Parameter-Datei) (Zeile n)
[Incorrect system number
(Q or R parameter file) (Line n)]
An error has occurred in line <n>.
The selected system does not exist.
-17
Falsche Achsnummer
(Q- oder R-Parameter-Datei) (Zeile n)
[Incorrect axis number
(Q or R parameter file) (Line n)]
An error has occurred in line <n>.
The selected axis does not exist.
-18
Steuerung befindet sich nicht im Resetzustand
(Q- Parameter-Datei)
[Controller not in reset status
(Q parameter file)]
Configuration data can only be
transferred if the control system is in
reset status: Carry out NC reset.
-19
Es konnten nicht alle NC-Programme gelöscht
werden
[Not possible to delete all NC programs]
Not possible to delete running
programs.
-20
MDI-Satz nicht möglich
[MDI record not possible]
NC must be in an automatic mode.
If an NC program is running the NC
must be in NC stop status.
There are also other particular
causes for this error message, e.g.
- Tool radius compensation active
- Threading cycle active
- RA, RB, RD record
- OCI record active
-21
Fehler beim Teachen
[Error while teaching]
Possible causes are:
- Maximum record length exceeded
(120 characters)
- An axis in the system has not been
referenced