9. Dedicated function
9-25
9.2.6 Error detection
Warnings or alarms are able to output by detecting position deviation error of own axis and
counterpart axis. Avoids continuance of servo motor rotation if motions between 2 axes have gap
by something cause.
■
Axes-sync error warning level
Warning outputs when position deviation error between own axis and counterpart axis
exceeds this set value.
✔
Warning status is able to check by the monitor indication and the front LED.
■
Axes-sync error excess value
Outputs the axes-sync error excess (alarm code: D4) when position deviation error between
own axis and counterpart axis exceeds this set value.
✔
Axes-sync error pulse is able to check by the monitor indication: ID66 Axes-sync
error monitor.
✔
Axes-sync error pulse is able to reset by the position deviation clear.
Group
ID
Setting range
Unit
B
80
1 to 2147483647
Pulse
Group
ID
Setting range
Unit
B
81
1 to 2147483647
Pulse