8.3 Trouble shooting when alarm activated
8-20
8
Maintenance
■
Alarm Code 62 (Main Circuit Under-voltage)
Corrective
actions
■
Alarm Code 63 (Main Power Supply phase loss)
Corrective
actions
■
Alarm Code 68 (Main circuit voltage detection error)
Corrective
actions
Status at the time of alarm
Cause
1
2
3
4
5
Issued when control power is turned ON.
✔
✔
Issued when main circuit power supply is
turned ON.
✔
✔
✔
Issued during operation.
✔
✔
Cause
Investigation and corrective actions
1
■
Input power supply voltage is below
the specified range.
■
Check the power supply and set it
within the specified range.
2
■
Rectifier of main circuit is broken.
■
Replace the servo amplifier.
3
■
Input power supply voltage is
reduced, or instantaneous power
interruption is occurred.
■
Check the power supply, and
confirm that there is no
instantaneous power interruption or
low voltage.
4
■
Low voltage outside of the specified
range is supplied to the main circuit
(R/S/T).
■
Check the main circuit voltage.
Confirm that there is no external
power supply to R/S/T when the
main circuit is OFF.
5
■
Defect in internal circuit of servo
amplifier.
■
Replace the servo amplifier.
Status at the time of alarm
Cause
1
2
3
Issued when control power is turned ON.
✔
Issued when main circuit power supply is
turned ON
✔
✔
✔
Issued during operation.
✔
✔
Cause
Investigation and corrective actions
1
■
One of 3 phases (R/S/T) is not
connected.
■
Check the wiring conditions and
correct it if improper.
2
■
Defect in internal circuit of servo
amplifier.
■
Replace the servo amplifier.
3
■
Servo amplifier is not specified for
single phase.
■
Change the system parameter ID01
" Main circuit power input type"
to ”01
:
AC_Single-phase”.
Status at the time of alarm
Cause
1
Issued when control power is turned ON.
✔
Cause
Investigation and corrective actions
1
■
Defect in internal circuit of servo
amplifier.
■
Replace the servo amplifier.
Содержание Sanmotion R 3E S
Страница 1: ...M0010630G For Rotary Motor Instruction Manual Analog Pulse Input Type ...
Страница 2: ......
Страница 76: ...No Text on This Page ...
Страница 88: ...No Text on This Page ...
Страница 266: ...No Text on This Page ...
Страница 332: ...No Text on This Page ...
Страница 408: ...No Text on This Page ...
Страница 444: ...No Text on This Page ...
Страница 482: ...12 Appendix 12 36 12 5 5 RS3A07A L 12 5 6 RS3A10A A 160 95 235 225 205 6 5 100 50 15 200 220 16 5 70 19 5 20 2 ...
Страница 511: ...12 7 Optional parts dimensions 12 65 12 Appendix REGIST 1000W Wiring diagram ...
Страница 512: ...No Text on This Page ...