64 Basic Operation
DKP-4016
Bosch Security Systems, Inc.
Technical Manual
F.01U.308.248 Rev. 03
User Programmable Buttons
A
UPG
(User Programmable Button)
gives you the option to assign frequently used menu items to a single button on the
keypanel, eliminating the need to navigate through the menu structure. Not all menu items can be programmed to the UPG
buttons, such as any assignment group menu, any TIF menu items, or scrolling menu items. Basically, any menu that requires
context or history cannot be saved. If a menu item cannot be saved, a prompt appears in the panel display showing
Cannot
save this menu position
.
NOTE:
You can program a UPG key to activate the screen saver option on the keypanel. For more information, see “To
activate the screen saver from a UPG key” on page 65.
The UPG keys can also be used to activate relays. When a relay is assigned to the button, and while the keypanel is not in
menu mode, pressing the UPG key activates the relay for as long as the UPG button is held down. Once the button is released,
the relay becomes inactive.
NOTE:
The UPG buttons can be cleared using Key Options|Clear from the keypanel menu.
IMPORTANT:
On the DKP-4016/4016W keypanel there are nine (9) UPG buttons available – UPG1 through 4 are
displayed on the keypad, while UPG 5 through 9 are available as the SHIFT version of the left column
buttons (MENU, FWD, BACK, UPG3, and UPG4).
To
assign a menu item to a UPG button on the DKP-4016/4016W
, do the following:
1.
On the DKP-4016/4016W keypad, press the
MENU button
.
The Information menu appears
.
2.
Using the arrow buttons, navigate to the
menu item
you want to assign to a UPG button.
3.
Press and hold the
UPG button
for two (2) seconds.
Menu position saved appears in the panel display
.
To
assign a menu item to a UPG button using the SHIFT menu
, do the following:
1.
On the keypad, press the
MENU button
.
The Information menu appears
.
2.
Using the arrow buttons, navigate to the
menu item
you want to assign to a UPG button.
3.
Press the
SHIFT button
and then hold the
UPG button
for two (2) seconds.
Menu position saved appears in the panel display
.
To
assign a relay to a UPG button
, do the following:
1.
On the DKP-4016/4016W keypad, press the
MENU button
.
The Information menu appears
.
2.
From the Information menu, using the arrow buttons, select
Service
.
3.
Press the
SEL button
.
The Service menu appears
.
4.
Using the arrow buttons, select
Local GPIO
.
5.
Press the
SEL button
.
GPIO Inputs and GPIO Outputs appears in the panel display.
6.
Using the arrow buttons, select
GPIO Outputs
.
7.
Press the
SEL button
.
Relay 1 and Relay 2 appear in the panel display.
8.
Using the arrow buttons, select the
Relay 1,
or
Relay 2
.
9.
Press the
SEL button
.
Not Assigned, Talk Key, and UPG 1 through UPG 9 appears in the panel display
.
Содержание DKP-4016
Страница 4: ...Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03 4 DKP 4016...
Страница 8: ...Bosch Security Systems Inc Technical Manual 8 DKP 4016 Rev 03 F 01U 308 248...
Страница 18: ...18 Introduction DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 30: ...30 Installation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 174: ...174 Firmware Download DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 244: ...244 DKP 4016 Menu System DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 250: ...250 Telephone Interface TIF Operation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 254: ...254 Keypad Quick Reference DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 278: ...278 DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 282: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com...