186 DKP-4016 Menu System
DKP-4016
Bosch Security Systems, Inc.
Technical Manual
F.01U.308.248
Rev. 03
Nominal inputs are as follows:
AUX 1
8dBu
Headset Mics
-50dBu
Matrix In
8dBu
Panel Mics
-42.5dBu
OMNEO 1-2
1
8dBu
To
configure gating on the keypanel
, do the following:
1.
Starting at the Audio Options|Advanced menu, select
Gating
.
2.
Press the
SEL button
.
Aux 1, Front Mic, Left Hdst, Matrix In, OMNEO 1, OMNEO 2, Rear Mic, and Right Hdst appear in the panel display.
(OMNEO 1-8 appears if Audio Package is installed)
3.
Using the left or right arrow buttons, select
Aux 1
,
Front Mic
,
Left Hdst
,
Matrix In
,
OMNEO 1
,
OMNEO 2
,
Rear
Mic
, or
Right Hdst
.
(OMNEO 1-8 appears Audio Package is installed)
4.
Press the
SEL button
.
The Threshold scroll menu appears.
5.
Using the up and down arrow buttons, select the
threshold
you desire.
6.
Press
BACK
to go to the previous menu item
OR
Press and hold
CLR
to exit the menu structure.
Metering
Metering
allows you to monitor an audio source connected to the keypanel. The energy of the incoming audio is split into
five (5) bands and displayed on the left side of the keypanel when enabled.
The decibels display range is from 28dB below nominal to 8dB above nominal
The bands are defined as:
Band 1
100 Hz to 400 Hz
Band 2
400 Hz to 800 Hz
Band 3
800 Hz to 1.6 kHz
Band 4
1.6 kHz to 3.2 kHz
Band 5
3.2 kHz to 15 kHz
NOTE:
Only one (1) channel can be metered at a time.
1.
OMNEO 1-8 appears if Audio Package is installed.
Содержание DKP-4016
Страница 4: ...Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03 4 DKP 4016...
Страница 8: ...Bosch Security Systems Inc Technical Manual 8 DKP 4016 Rev 03 F 01U 308 248...
Страница 18: ...18 Introduction DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 30: ...30 Installation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 174: ...174 Firmware Download DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 244: ...244 DKP 4016 Menu System DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 250: ...250 Telephone Interface TIF Operation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 254: ...254 Keypad Quick Reference DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 278: ...278 DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 282: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com...