86 Basic Operation
DKP-4016
Bosch Security Systems, Inc.
Technical Manual
F.01U.308.248 Rev. 03
Keypanel Mirroring (Control Package Only)
Keypanel Mirroring
allows a licensed DKP-4016/4016W keypanel (licensed as a supervisor) to take control of a target
keypanel. All KP-Series keypanels can be the target of mirroring, whereas only licensed keypanels can be the supervisor of a
target keypanel. By default, Keypanel Mirroring is disabled, You must enable a panel to be a mirror supervisor using AZedit.
This allows any licensed keypanel to initiate a mirroring operation on a local target keypanel.
IMPORTANT:
Mirroring is not supported across trunks.
Keypanel Mirroring operates in real-time, meaning when a supervisor keypanel initiates a mirroring operation almost all
aspects of the target keypanel functionality are accessible. Once the configuration file is transferred from the target to the
supervisor keypanel, the supervisor keypanel looks and behaves like the target. Turning keys on/off, adjusting key volumes or
panel volumes on either the target or supervisor keypanel is seen immediately on the other keypanel.
IMPORTANT:
If using a DKP to mirror a KP-5032, you do not have access to keys 1-9 or 17-25 because the DKP only
mimics the right side of the full 2RU panel.
On the target keypanel, the keypad is locked out, preventing the target keypanel from entering the menu. Any changes to the
configuration made by the supervisor keypanel are immediately transferred to the target keypanel.
IMPORTANT:
The Supervisor keypanel can change settings for features the Target is licensed for, even if the
Supervisor is not licensed. Compression ratios, additional noise gate settings, and the 5-band equalizer
settings are all available in the Supervisor (even if it is not licensed for these features) as long as the
Target panel is licensed for them. For example, if the target keypanel supports a 5-band EQ and the
supervisor keypanel does not, the supervisor keypanel is able to change the EQ settings.
In AZedit, if a keypanel is a mirror Supervisor or Target, an icon is shown in the Port Status area in the Keypanel View.
IMPORTANT:
If you make changes, including real time changes, to a Target Keypanel using AZedit, those changes are
also seen on the Supervisor Keypanel. However, if you make changes, including real-time changes, to a
Supervisor Keypanel using AZedit, those changes are made to the Supervisor’s saved configuration, but
are not implemented until the Supervisor Keypanel exits Mirroring and returns to normal operation.
Supervisor icon
The Supervisor icon signifies the keypanel is mirroring another keypanel and can
make changes to the other keypanel, known as a Target. For more information, see
“Service Menu, Mirror (Control Package Only)” on page 234.
Target icon
The Target icon signifies the keypanel is being mirrored by another keypanel, known
as a Supervisor. This keypanel is being remotely controlled by the Supervisor. For
more information, see “Service Menu, Mirror (Control Package Only)” on page 234.
****These icons appear on the keypanels involved in the mirror operation.
Содержание DKP-4016
Страница 4: ...Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03 4 DKP 4016...
Страница 8: ...Bosch Security Systems Inc Technical Manual 8 DKP 4016 Rev 03 F 01U 308 248...
Страница 18: ...18 Introduction DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 30: ...30 Installation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 174: ...174 Firmware Download DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 244: ...244 DKP 4016 Menu System DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 250: ...250 Telephone Interface TIF Operation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 254: ...254 Keypad Quick Reference DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 278: ...278 DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 282: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com...