Navigation Mode for Panel Swap
Once you have selected the control trigger, select what panel swap action is performed:
Cycle To
Cycle to the Next or Previous panel.
Switch To
Switch to a specific panel (for example, MAIN, EKP1, EKP2, etc.
The following icon appears briefly when the Main page is showing
.
The following icon appears when the first virtual EKP is showing
. Subsequent virtual
EKPs display their number in the icon.
Toggle To
Toggle between MAIN and a specific virtual EKP.
Unassigned
Used to erase the panel swap action from a trigger or control mechanism.
Panel Swap Key States
Key States
define what happens to the key states when a row of keys is not currently visible. There are two (2) possible modes
of operation:
Force Off
Talk and listen key states are forced off when the row of keys is not visible.
Retain
Talk and listen key states are retained when the row of keys is not visible.
When retain is selected and active talk or listen keys are not visible, the following icon shows in the panel
display.
In the menu structure, under Panel Swap, the menu items Control and Key States appear, but are unavailable on the keypanel
until one (1) or more virtual EKPs are enabled.
To
enable virtual keypanels
, do the following:
1.
Starting at the Key Options|Panel Swap menu, select
Virtual EKPs
.
2.
Press the
SEL button
.
None, 1 EKP, 2 EKPs, etc appear in the panel display.
IMPORTANT:
The number of virtual EKPs that appear in the selections depends on the number of keys per port the
intercom is configured for.
3.
Using the arrow buttons,
select the
maximum number of virtual EKPs to enable
.
4.
Press the
SEL button
.
An arrow appears next to the selected option.
To
configure how to access the virtual EKPs from the front of the keypanel
, do the following:
1.
Starting at the Key Options|Panel Swap menu, select
Control
.
2.
Press the
SEL button
.
GPI Inputs, GPI Outputs, and Keypad appear in the panel display.
3.
Using the arrow buttons,
select the
control mechanism
desired.
4.
Press the
SEL button
.
The appropriate sub-control mechanism appears (see “Panel Swap Control Options” on page 218).
5.
Using the arrow buttons,
select the
sub-control mechanism
.
6.
Press the
SEL button
.
Cycle To, Switch To, Toggle To, and Unassigned appear in the panel display.
7.
Using the arrow buttons,
select the
navigation mode
desired.
Содержание DKP-4016
Страница 4: ...Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03 4 DKP 4016...
Страница 8: ...Bosch Security Systems Inc Technical Manual 8 DKP 4016 Rev 03 F 01U 308 248...
Страница 18: ...18 Introduction DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 30: ...30 Installation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 174: ...174 Firmware Download DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 244: ...244 DKP 4016 Menu System DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 250: ...250 Telephone Interface TIF Operation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 254: ...254 Keypad Quick Reference DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 278: ...278 DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 282: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com...