Service Menu, Mirror (Control Package Only)
The
Mirror
menu provides a scroll list of keypanels which can be the target of a mirror operation. All KP-Series units can be
a mirror target, a license is not required for targets.
NOTE:
This menu option is not shown if the port has mirroring disabled. See “Keypanel Mirroring (Control Package
To
take control of a target keypanel
, do the following:
1.
On the keypanel, starting at the Service menu, select
Mirror
.
2.
Press the
SEL button
.
A list of available target keypanels appear in the panel display
.
IMPORTANT:
Only panels that are locally scroll enabled are display in the available target keypanels list. If they are
not in your scroll list, you cannot mirror them.
3.
Using the arrow buttons, scroll to the
target keypanel
.
4.
Press the
SEL button
.
The Supervisor keypanel updates and displays the target keypanel’s image.
To
exit Mirror mode
on the keypanel
, do the following:
1.
On the keypanel, starting at the Service menu, select
Mirror
.
2.
Press the
SEL button
.
The alpha of the target and Exit appear in the panel display
.
3.
Using the arrow buttons or Aux Volume shaft encoder, select
Exit
.
4.
Press the
SEL button
.
The mirroring target and supervisor icons disappear and keypanels go back to normal operation.
Service Menu, OMNEO Setup
The
OMNEO Setup
menu option is used to configure the OMNEO device name, enable DHCP, address the OMNEO device
for the keypanel and set up the static IP configuration, if DHCP is disabled.
IMPORTANT:
If you change the device name on the keypanel, you must change how other devices are configured, so
they can continue to make connection offers to this keypanel.
To
enable DHCP from the keypanel
, do the following:
1.
Starting at the Service|OMNEO Setup menu, select
OKP
.
NOTE:
OKP refers to the OMNEO keypanel using the OMNEO connection; however, if an OEI-2 is also attached to
the AIO port, you see both OKP and OEI-2 options for selection.
2.
Press the
SEL button
.
Device Name, DHCP, and IP Parameters appear in the panel display
.
3.
Using the arrow buttons,
select
DHCP
.
4.
Press the
SEL button
.
Disabled and Enabled appear in the panel display.
5.
Using the arrow buttons,
select
Enabled
.
6.
Press the
SEL button
.
7.
Press the
CLR
button to exit the menu.
Содержание DKP-4016
Страница 4: ...Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03 4 DKP 4016...
Страница 8: ...Bosch Security Systems Inc Technical Manual 8 DKP 4016 Rev 03 F 01U 308 248...
Страница 18: ...18 Introduction DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 30: ...30 Installation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 174: ...174 Firmware Download DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 244: ...244 DKP 4016 Menu System DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 250: ...250 Telephone Interface TIF Operation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 254: ...254 Keypad Quick Reference DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 278: ...278 DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 282: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com...