DKP-4016
Basic Operation 129
Bosch Security Systems, Inc.
Technical Manual
F.01U.308.248 Rev. 03
Mic Options Group Box
The
Mic Options
group box is used to choose how audio is routed to the Preamp Output connector, configure the actions of
the Mic Mute key, to enable or disable mic gain on the keypanel, and to configure AEC
1
(Acoustic Echo Cancellation)
prioritization on a microphone.
•
For further explanation of the available selections for the Mic Preamp Mode drop down menu, see
“Audio Options Menu, Preamp Out” on page 199.
•
For further explanation of the available selections for the Mic Mute Mode drop down menu, see “Audio
Options Menu, Mic Mute” on page 198.
•
For further explanation of the available selections for the Mic Gain Adjust Source drop down menu, see
“Audio Options Menu, Mic Gain” on page 197.
•
For further explanation of the available selection for the AEC Mic Priority drop down menu, see “AEC”
on page 178.
To
configure mic options
, do the following:
1.
From the Mic Preamp Mode drop down menu, select
Switched
,
Hot
,
Disabled
, or
Inverted
.
2.
From the Mic Mute Mode drop down menu, select
Disabled
,
Toggle
, or
Momentary
.
3.
From the Mic Gain Adjust Source drop down menu, select the
mic gain adjust source
.
4.
From the AEC Mic Priority drop down menu, select
front
or
rear
.
1. AEC is used to prevent feedback from occurring between the microphone and the speaker.
FIGURE 58.
Audio Options Page – Mic Options Group Box
Содержание DKP-4016
Страница 4: ...Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03 4 DKP 4016...
Страница 8: ...Bosch Security Systems Inc Technical Manual 8 DKP 4016 Rev 03 F 01U 308 248...
Страница 18: ...18 Introduction DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 30: ...30 Installation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 174: ...174 Firmware Download DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 244: ...244 DKP 4016 Menu System DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 250: ...250 Telephone Interface TIF Operation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 254: ...254 Keypad Quick Reference DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 278: ...278 DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 282: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com...