236 DKP-4016 Menu System
DKP-4016
Bosch Security Systems, Inc.
Technical Manual
F.01U.308.248
Rev. 03
To
configure the OKP IP parameters
, do the following:
1.
Starting at the Service|OMNEO Setup menu, select
OKP
.
2.
Press the
SEL button
.
Device Name, DHCP, and IP Parameters appear in the panel display
.
3.
Using the arrow buttons, select
DHCP
.
4.
Press the
SEL button
.
Disabled and Enabled appear in the panel display.
5.
Verify DHCP is
disabled
.
NOTE:
When making changes to the OKP IP parameters, DHCP must be disabled before changing the name or IP
Address. If DHCP is enabled, you can still view the IP Parameters, but you cannot make changes to them.
6.
Press
BACK
.
7.
Using the arrow buttons,
select
IP Parameters
.
NOTE:
SEL/FWD moves to the next octet, unless already on the last octet, in which case it save the current IP
Address. CLR/BACK moves to the previous octet, unless already on the first octet, in which case it cancels
editing of the IP Address.
8.
Press the
SEL button
.
IP Address, Gateway, Netmask, Domain, and DNS Server appear in the panel display.
9.
Press the
SEL button
.
The IP Address appears with the first octet blinking in the panel display.
10.
Using the number pad, enter the
first octet number
in the IP Address.
11.
Press the
SEL button
.
The focus shifts to the second octet
.
12.
Using the number pad, enter the
second octet number
in the IP Address.
13.
Press the
SEL button
.
The focus shifts to the third octet
.
14.
Using the number pad, enter the
third octet number
in the IP Address.
15.
Press the
SEL button
.
The focus shifts to the last octet
.
16.
Using the number pad, enter the
last octet number
in the IP Address.
17.
Press the
SEL button
.
The OKP Setup menu options appear in the panel display
.
Содержание DKP-4016
Страница 4: ...Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03 4 DKP 4016...
Страница 8: ...Bosch Security Systems Inc Technical Manual 8 DKP 4016 Rev 03 F 01U 308 248...
Страница 18: ...18 Introduction DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 30: ...30 Installation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 174: ...174 Firmware Download DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 244: ...244 DKP 4016 Menu System DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 250: ...250 Telephone Interface TIF Operation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 254: ...254 Keypad Quick Reference DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 278: ...278 DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 282: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com...