232 DKP-4016 Menu System
DKP-4016
Bosch Security Systems, Inc.
Technical Manual
F.01U.308.248
Rev. 03
Service Menu, LCD Backlight
The
LCD Backlight
menu option allows you to set the brightness of the panel display of all keypanels, just the main panel or
any expansion panel connected to the main keypanel.
The range for this field is
0–100%.
The default is
65%
.
To
configure the LCD backlight
, do the following:
1.
Starting at the Service|Keypad menu, select
LCD
Backlight
.
2.
Press the
SEL button
.
The Brightness scroll box appears in the panel display.
3.
Using the up and down arrow buttons, select the
brightness
you want to display.
Service Menu, Local GPIO
Local GPIO
is used to configure GPIO inputs and outputs. Inputs can be assigned to activate intercom keys (including group
master keys). Outputs can be activated by talk or UPG keys.
Further configuration can be done to allow GPIO Inputs to track the state of the Output. For example, an output is activated
(and is being tracked by an input), the input is also activated. This feature allows GPIO Outputs to control Talk Key or Key
Group activation.
In addition to tracking, you can also configure the way an Input GPIO Key Group is configured. By default, when a key group
is activated, the keys are forced on until the key group is deactivated. This is referred to as Level Mode. Alternatively, you can
configure the key group to Edge Mode. This option turns on keys in a key group when the group is activated, but allows the
user to turn off individual keys even if the key group is still active.
To
configure a GPIO Input to control an individual talk key
, do the following:
1.
Starting at the Service|Local GPIO menu, select
GPIO Inputs
.
2.
Press the
SEL button
.
Opto 1 and Opto 2 appear in the panel display
.
3.
Using the arrow buttons,
select
Opto 1
or
Opto 2
.
4.
Press the
SEL button
.
Function and Mode appear in the panel display.
5.
Using the arrow buttons, select
Function
.
6.
Press the
SEL button
.
Key Group, Not Assigned, and Talk Key appear in the panel display.
7.
Using the arrow buttons,
select
Talk Key
.
8.
Press the
SEL button
.
Tap Key appears in the panel display.
9.
Tap the
talk key
to be controlled by the GPIO Input.
The selected keypanel key red talk indicator LED appears.
To
configure a GPIO Input to control a Key Group
, do the following:
1.
Starting at the Service|Local GPIO menu
,
select
GPIO Inputs
.
2.
Press the
SEL button
.
Opto 1 and Opto 2 appear in the panel display
.
3.
Using the arrow buttons,
select
Opto 1
or
Opto 2
.
4.
Press the
SEL button
.
Function and Mode appear in the panel display.
5.
Using the arrow buttons, select
Function
.
Содержание DKP-4016
Страница 4: ...Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03 4 DKP 4016...
Страница 8: ...Bosch Security Systems Inc Technical Manual 8 DKP 4016 Rev 03 F 01U 308 248...
Страница 18: ...18 Introduction DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 30: ...30 Installation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 174: ...174 Firmware Download DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 244: ...244 DKP 4016 Menu System DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 250: ...250 Telephone Interface TIF Operation DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 254: ...254 Keypad Quick Reference DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 278: ...278 DKP 4016 Bosch Security Systems Inc Technical Manual F 01U 308 248 Rev 03...
Страница 282: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com...