The INT-S-GR and INT-S-BL partition keypads are designed for work in conjunction with 
INTEGRA and CA-64 alarm control panels. They differ in the backlight color of their keys, 
which is green in the INT-S-GR and blue in the INT-S-BL. The partition keypads are used to 
control the arming mode in one partition, to perform a function of monitoring access and 
controlling operation of the electromagnetic door locks, as well as monitoring closure of those 
doors. The keypads make it possible to change the user code and call the functions 
controlling the external devices. 
This manual applies to the partition keypad with firmware version 1.2. 

1.  Description of partition keypad 

The partition keypad has 12 keys with permanent or temporary (automatically activated) 
mode backlight and LED indicators. 
 

LED designation: 

 

ALARM

 (red color) - steady light 

indicates an alarm in the keypad 
controlled partition, while blinking 
indicates that an alarm was triggered 
in the partition. 

 - 

ARMED

 (green color) - steady light 

indicates that the partition to which the 
keypad is assigned has been armed. 
Blinking indicates countdown of the 
exit delay. 

 - 

TROUBLE

 (yellow color) – blinking 

indicates that a technical problem has 
occurred. The signaling applies to 
troubles from the entire alarm system, 
not only from the keypad controlled 
partition. The type of trouble can be 
checked on the LCD keypad. Arming 
the keypad controlled partition will 
disable the trouble signaling. 
Disarming the partition will restore the 
trouble signaling. 

 

 

Figure 1. Partition keypad. 

 
Alternative blinking of all the LEDs (from top to bottom) indicates lack of communication 
between the keypad and the control panel. This situation may take place when the STARTER 

Содержание INT-S-BL

Страница 1: ...temporary automatically activated mode backlight and LED indicators LED designation ALARM red color steady light indicates an alarm in the keypad controlled partition while blinking indicates that an...

Страница 2: ...eypad 3 tamper contact The spring should be pressed against the wall 4 buzzer Figure 2 Schematic view of the keypad electronics board 2 Installation and Connection of the Module Note Prior to hookup o...

Страница 3: ...ol sensor to the IN and COM terminals 8 If the keypad is to serve as a code lock connect the wires to control the electromagnetic door lock or another device to the NO terminals 9 Close the casing 3 S...

Страница 4: ...nt of the keypad to a partition selected from the list Lock feature the option available in the LCD keypad its activation provides access to the Lock submenu Lock DLOADX Lock feature DLOAD64 its activ...

Страница 5: ...y contacts NO the NO contacts are normally open they close on activating the relay during its active state NC the N contacts are normally closed they open on activating the relay during its active sta...

Страница 6: ...ling the countdown of the auto arming delay in the partition it has been assigned to Access code signaling hardware enabling this option will activate the signaling of code entry acknowledgement which...

Страница 7: ...ive not cleared tamper alarms This prevents multiple recording of the same events in the control panel memory The option allows this feature to be disabled 5 Technical Data Nominal supply voltage 15 1...

Страница 8: ...est EC declarations of conformity and certificates are available for downloading on the website www satel pl SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www s...

Отзывы: