5. SETTING
IMR01Y09-E3
24
List of communication environment setting items
Node address setting switch MSD
Node address setting switch LSD
No.
Setting item
Data range
Factory
set value
0
Action mode selection
Address setting method
0: Continuous
setting
1
1: Free
setting
1
2: Continuous
setting
2
3: Free
setting
2
4 to 9: Don’t set this one
Continuous setting:
The addresses that are set in object
instances 1 to 31 of the controller address
settings* must be set in order from the
lowest instance.
Free setting:
The addresses that are set in object
instances 1 to 31 of the controller address
settings* can be set freely.
* The Attribute ID: 246 of controller object
(0x64: 64Hex).
0
1
Number of polling I/O
communication controllers
0: 1
controller
1 to 8: 2 to 30 controllers
(
=
set value
×
4
−
2)
9: 31
controllers
Set the number of controller
communicating by polling I/O
communication.
10
controllers
2
Unused
Don’t set this one
3
Unused
Don’t set this one
4
Number of communication
measured data items (IN) when
conducting polling I/O
communication
0 to 8: 0 to 80 words (
=
set value
×
10)
9: 200
words
Set the number of measured data items (IN)
communicating via polling I/O
communication.
0:
Depends on
the DIP
switch setting
(7 words)
5
Number of communication setting
data items (OUT) when
conducting polling I/O
communication
0 to 8: 0 to 80 words (
=
set value
×
10)
9: 200
words
Set the number of setting data items (OUT)
communicating via polling I/O
communication.
0:
Depends on
the DIP
switch setting
(7 words)
1
The PID/AT transfer by polling I/O communication is invalid.
2
The PID/AT transfer by polling I/O communication is valid.
Continued on the next page.