APPENDIX
IMR01Y09-E3
105
Continued from the previous page.
ID
Description
Get
Set
Type
Value
Attributes
208 ST start condition
Yes
Yes
INT
See P. 69
209
Automatic
temperature
rise group
Yes
Yes
INT
See P. 69
210 Automatic temperature rise learning
Yes
Yes
INT
See P. 69
211
Automatic
temperature
rise
dead time
Yes
Yes
INT
See P. 70
212 Automatic temperature rise gradient data
Yes
Yes
INT
See P. 70
213 RUN/STOP group
Yes
Yes
INT
See P. 70
214 Setting change rate limiter unit time
Yes
Yes
INT
See P. 70
215 Soak time unit
Yes
Yes
INT
See P. 70
216 Setting limiter (high)
Yes
Yes
INT
See P. 70
217 Setting limiter (low)
Yes
Yes
INT
See P. 70
218 PV transfer function
Yes
Yes
INT
See P. 70
219 PV flashing display at input error
Yes
Yes
WORD
See P. 70
220
Unused
No
No
UINT
221
Unused
No
No
UINT
222
Unused
No
No
UINT
223
Unused
No
No
UINT
224
Unused
No
No
INT
225 Controller state 1
Yes
No
WORD
See P. 70
226 Controller state 2
Yes
No
WORD
See P. 71
227 Controller state 3
Yes
No
WORD
See P. 71
228
Unused
1
No
No
UINT
229
Unused
1
No
No
UINT
230
Unused
1
No
No
UINT
231 Comprehensive alarm state
2, 3
Yes
No
WORD
See P. 71
232 Controller alarm state
2, 4
Yes
No
WORD
See P. 72
233
Error
state
2, 4
Yes
No
WORD
See P. 72
234
RUN/STOP
2, 4
Yes
Yes
WORD
See P. 72
235 Setting update flag
2, 3
Yes
No
WORD
See P. 72
236 Number of polling I/O
communication controllers
2, 3, 5
Yes
Yes
UNIT
See P. 72
237
Unused
No
No
UINT
238 COM-JH error code
2, 3, 6
Yes
No
WORD
See P. 72
1
If this data item is set as a measured data item (IN) or setting data item (OUT) by the “Controller
communication item setting object (0xC7: C7Hex)” which sets communication data items via polling
I/O communication, it becomes the same as that when set at “0.” In addition, any data item set hereafter
is invalidated.
2
It is validated only via Explicit message communication. If this data item is set as a measured data item
(IN) or setting data item (OUT) by the “Controller communication item setting object (0xC7: C7Hex)”
which sets communication data items via polling I/O communication, it becomes the same as that when
set at “0.” In addition, any data item set hereafter is invalidated.
3
Only object instances 1 is valid.
4
Only object instances 1 and 2 are valid.
5
Data for the set number of controllers is assigned by polling I/O communication. The number of
assigned data items is the number of data items for the set number of modules in each item of the
attributes set in “Controller communication item setting object (0xC7: C7Hex).”
6
Causes of controller communication errors
−
No controllers are connected.
−
“0” is set for all controller addresses.
−
The controller timed-out after recognition.
−
An abnormal condition exists in communication.
Continued on the next page.