APPENDIX
IMR01Y09-E3
101
Continued from the previous page.
ID
Description
Get
Set
Type
Value
Attributes
31
Unused
No
No
UINT
0 to 65535
32
Unused
No
No
UINT
0 to 65535
33
PID/AT
transfer
1, 2
Yes
Yes
INT
See P. 47
34
Auto/Manual transfer
Yes
Yes
INT
See P. 47
35
Remote/Local transfer
Yes
Yes
INT
See P. 47
36
RUN/STOP
transfer
3
Yes
Yes
INT
See P. 47
37
Memory area transfer
Yes
Yes
INT
See P. 47
38
Interlock release
Yes
Yes
INT
See P. 47
39
Event 1 set value (EV1)
Yes
Yes
INT
See P. 48
40
Event 2 set value (EV2)
Yes
Yes
INT
See P. 48
41
Event 3 set value (EV3)
Yes
Yes
INT
See P. 48
42
Event 4 set value (EV4)
Yes
Yes
INT
See P. 48
43
Control loop break alarm (LBA) time
Yes
Yes
INT
See P. 48
44
LBA deadband
Yes
Yes
INT
See P. 48
45
Set value (SV)
Yes
Yes
INT
See P. 48
46
Proportional band [heat-side]
Yes
Yes
INT
See P. 48
47
Integral time [heat-side]
Yes
Yes
INT
See P. 48
48
Derivative time [heat-side]
Yes
Yes
INT
See P. 49
49
Control response parameter
Yes
Yes
INT
See P. 49
50
Derivative time [cool-side]
Yes
Yes
INT
See P. 49
51
Proportional band [cool-side]
Yes
Yes
INT
See P. 49
52
Integral time [cool-side]
Yes
Yes
INT
See P. 49
53
Overlap/Deadband
Yes
Yes
INT
See P. 50
54
Manual reset
Yes
Yes
INT
See P. 50
55
Setting change rate limiter (up)
Yes
Yes
INT
See P. 50
56
Setting change rate limiter (down)
Yes
Yes
INT
See P. 50
57
Area soak time
Yes
Yes
INT
See P. 50
58
Link area number
Yes
Yes
INT
See P. 50
59
Heater break alarm 1 (HBA1) set value
Yes
Yes
INT
See P. 50
60
Heater break determination point 1
Yes
Yes
INT
See P. 50
61
Heater melting determination point 1
Yes
Yes
INT
See P. 51
62
Heater break alarm 2 (HBA2) set value
Yes
Yes
INT
See P. 51
63
Heater break determination point 2
Yes
Yes
INT
See P. 51
64
Heater melting determination point 2
Yes
Yes
INT
See P. 51
65
PV bias
Yes
Yes
INT
See P. 51
66
PV digital filter
Yes
Yes
INT
See P. 51
67
PV ratio
Yes
Yes
INT
See P. 51
68
PV low input cut-off
Yes
Yes
INT
See P. 51
1
It is validated only via Explicit message communication. If “PID/AT transfer” is set as the setting
data item (OUT) by the “Controller communication item setting object (0xC7: C7Hex)” which sets
communication data items via polling I/O communication, it becomes the same as that when set at
“0.” If set as the measured data item (IN), it can be used as is.
2
When using PID/AT transfer by polling I/O communication, it is necessary to set action mode
selection (Attributes ID: 246) to "PID/AT transfer by polling I/O communication is valid."
3
If “RUN/STOP transfer” is set as the setting data item (OUT) by the “Controller communication
item setting object (0xC7: C7Hex)” which sets communication data items via polling I/O
communication, it becomes the same as that when set at “0.” If set as the measured data item (IN), it
can be used as is.
Continued on the next page.