RISO Inc. Technical Communications
us.riso.com
CHAPTER 9: CLAMP UNIT
[ 9 - 8 ]
3. Removing the Clamp Sensors A & B
(1) Switch off the machine power, remove the rear cover, and swing open the PCB bracket of the power
supply PCB and mechanical control PCB.
(2) Detach the clamp unit.
(3) Unplug the reusable band (1pc) from the clamp unit.
(4) Remove a screw (M3x6: 1pc) and detach the clamp sensor plate with the two sensors attached.
(5) Unplug the connectors and unhook and remove each sensor from the clamp sensor plate.
Clamp sensor-A
Clamp sensor plate
Reusable band
Clamp sensor-B
0914
Содержание RZ2xx Series
Страница 16: ...RISO Inc Technical Communications us riso com CHAPTER 1 MAINTENANCE 1 14 MEMO ...
Страница 36: ...RISO Inc Technical Communications us riso com 2 20 CHAPTER 2 MACHINE SUMMARY ...
Страница 38: ...RISO Inc Technical Communications us riso com 2 22 CHAPTER 2 MACHINE SUMMARY MEMO ...
Страница 52: ...RISO Inc Technical Communications us riso com CHAPTER 3 MAIN DRIVE 3 14 MEMO ...
Страница 78: ...RISO Inc Technical Communications us riso com CHAPTER 4 FIRST PAPER FEED SECTION 4 26 MEMO ...
Страница 98: ...RISO Inc Technical Communications us riso com CHAPTER 5 SECOND PAPER FEED SECTION 5 20 MEMO ...
Страница 190: ...RISO Inc Technical Communications us riso com CHAPTER 10 MASTER REMOVAL SECTION 10 22 MEMO ...
Страница 272: ...RISO Inc Technical Communications us riso com CHAPTER 14 MASTER MAKING SECTION 14 40 MEMO ...
Страница 278: ...RISO Inc Technical Communications us riso com 15 6 CHAPTER 15 OTHER PRECAUTIONS MEMO ...
Страница 312: ...RISO Inc Technical Communications us riso com CHAPTER 16 PANEL MESSAGE 16 34 MEMO ...
Страница 360: ...RISO Inc Technical Communications us riso com CHAPTER 19 WIRING DIAGRAM RZ2 SERIES 19 14 MEMO ...
Страница 374: ...RISO Inc Technical Communications us riso com ...