Regency GF950L-2 Gas Fireplace
55
920-276c
10.29.20
WARNING
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer’s
instructions and all applicable codes and require-
ments of the authority having jurisdiction. If these
instructions is not followed exactly, a fire, explosion
or production of carbon monoxide may result causing
property damage, personal injury or loss of life. The
qualified service agency is responsible for the proper
installation of this kit. The installation is not proper
and complete until the operation of the converted ap-
pliance is checked as specified in the manufacturer’s
instructions supplied with the kit.
Conversion Kit includes:
1
911-339
Wiring Harness
1
946-765 or 946-542
Power Flue
1
910-327
Strain Relief
Natural Non Power Flue to Power Flue Conversion follow steps below:
1. Install either Inline/End of line power flue systems first. Refer to the gas
power flue installation instructions based on your type of power flue
system that will be used. Once the flue system has been installed the
wire harness may then be brought to the appliance as per steps below.
2. Run the power flue wire harness from the inline/end of line power flue to
the appliance. Excess wire can be rolled up as shown below and placed
where space is available such as in an attic space, or within a chase.
5. Run the wires into the appliance until the strain relief mounting plate is
reached. Screw the mounting plate onto the appliance using 4 supplied
Phillips head screws.
4. Insert the power flue wire harness through the square opening.
3. Locate the opening on the left hand side of the appliance beside the
power cord.
6. Remove the 4 Phillips head screws on the front panel plate to gain access
to the ECS V control module.
7. Remove the nut on the grounding screw located on the left hand side of
the appliance and connect the additional ground wire from the power flue
wire harness. Reinstall the grounding screw nut.
1
GF950 ECS V
Natural Vent to Power Vent Conversion
WARNING
ELECTRICAL CONNECTIONS SHOULD ONLY BE CARRIED OUT BY A QUALIFIED AND LICENSED ELECTRICIAN
Natural Flue to Power Flue Conversion
NATURAL FLUE TO POWER FLUE CONVERSION