22
Regency GF950L-2 Gas Fireplace
installation
Flue restriction is required for certain flueing installations, see the diagrams
in the "Flueing
Arrangements" section to determine if they are required for your installation.
The Flue Restrictor plate is located on the inside top of the firebox.
To set the flue restriction as indicated in the flueing arrangements diagrams,
refer to the following instructions;
1. Remove the glass door and inner panels - see instructions in this manual.
2. Remove 6 screws (3 front - 3 back) to remove heat baffle to access restrictor
plate.
3. Remove the screws that hold the flue restrictor in place.
FLUE RESTRICTOR POSITION
Heat Baffle
4. Adjust the flue restrictor plate to the required flue restrictor position as per
the diagrams shown below.
5. Once the flue restrictor plate is in the required position, secure with screws.
FLUE RESTRICTOR SETTING
Set 0 - 75mm Open
(Factory Setting)
Set 2 - 25mm open
Set 3 - 18mm open
Set 1 - 50mm open
Содержание Greenfire GF950L Series
Страница 93: ...Regency GF950L 2 Gas Fireplace 93 NOTES notes ...
Страница 100: ......
Страница 101: ...Regency GF950L 2 Gas Fireplace 101 NOTES notes ...
Страница 102: ...102 Regency GF950L 2 Gas Fireplace NOTES notes ...
Страница 103: ......