Regency GF950L-2 Gas Fireplace
63
Install the flue system according to the manufacturer's
instructions included with the components.
1. Set the unit in its desired location. Check to
determine if wall studs or roof rafters are in the
way when the flueing system is attached. If this
is the case, you may want to adjust the location
of the unit. Rough in the gas preferably on the
right side of the unit and the electrical (junction
block is on the left side) on the left.
2. Direct Vent pipe and fittings are designed with
special twist-lock connections to connect the
flueing system to the appliance flue outlet. A
twist-lock appliance adaptor is required.
3. In conjunction with the approved flue system,
install the adaptor after the unit is set in its
desired location. Put a bead of Mill-Pac inside
the outer section of the adapter and a bead of
Mill-Pac on the inner collar. Slip the adapter over
the existing inner and outer flue collar. Fasten to
the outer collar only with the 3 supplied screws
(drilling pilot holes will make this easier).
4. Level the fireplace and fasten it to the framing
using nails or screws through the top and side
nailing strips.
Diagram 1
Note: For best results and optimum
performance with each approved
flueing system, it is a minimum to
apply Mill-Pac sealant (supplied) to
every inner pipe connection. Failure
to do so may result in drafting or
performance issues not covered
under warranty.
Horizontal runs of flue must be supported
every 0.9 meter. Wall straps are available for
this purpose.
6. Mark the wall for a square hole - see chart to left
for size. The center of the square hole should
line up with the center-line of the horizontal pipe.
Cut and frame the square hole in the exterior
wall where the flue will be terminated.
5. Assemble the desired combination of pipe and
elbows to the appliance adaptor and twist-lock
for a solid connection.
Recommended Framed Opening Size
Flue Size
Framing Size
102mm x 168mm
254mm x 254mm
Horizontal Top*
76mm*
Horizontal Side
51mm
Horizontal Bottom
51mm
Vertical Flue
51mm
Minimum Flue Clearances
to Combustibles
UNIT INSTALLATION WITH HORI-
ZONTAL TERMINATION
END OF LINE POWER FLUE
102MM X 168MM RIGID FLUEING
Below are the recommended framing dimensions
(inside measurements) for the 102mm x 168mm
rigid flue terminations - for use with a firestop or
wall thimble.
* Clearances noted below must be maintained;
except when passing through a wall, ceiling or at
the termination where the use of a firestop or wall
thimble reduces clearance to 38mm.