84
Regency GF950L-2 Gas Fireplace
Replacing the capacitor:
1. Turn off power supply.
2. Loosen the following screws on the terminal block
and pull capacitor out.
3. Ensure the replacement capacitor leads are
inserted correctly into the terminal block with
the red and white wires coming from the power
flue harness.
END OF LINE POWER FLUE MAINTENANCE
INTERNAL POWER FLUE ACCESS
Note: May only be accessed if an access panel was installed for servicing from inside.
1. Turn off the power.
2. Remove 8 Phillips head screws from the rear of the power flue (see Diagram 1).
3. Slide the power flue housing out through the back as shown in Diagram 2.
4. Turn the power flue over to the front side (Diagram 3).
5. Follow Steps 1-9 on previous page.
Front of power flue
Diagram 1
Diagram 2
Diagram 3