Regency GF950L-2 Gas Fireplace
47
919-696
06.11.18
Used
in conjunction with the 946-7
6
5
Inline power flue
where a
maximum of 2 946-756 may be used up to a maximum of
12 meters
.
Only approved for power
flue
model
s
for any horizontal
terminations.
1. Stretch out both inner 10
2
mm and outer 1
68
mm pipe up to
a maximum of
6m
.
Note
:The inner and outer pipes may be cut if only a short length is required.
2.
Install spring spacers around 100mm inner pipe as shown.
Slide outer flex pipe over and all the way down the
100mm
pipe.
3.
Apply a bead of Mill Pac around the perimeter of the 100mm inner
collar of the flex adapter and slip the 100mm inner flex pipe from the
Vertical termination kit over the flex adapter ensuring that the inner flex
pipe overlaps the collar by at least 35mm. Fasten with 3 screws.
4.
Apply a bead of Mill Pac around the perimeter of the 1
68
mm outer
collar of
the flue adapter and slip it over the 168mm outer flex pipe
from the vertical
termination kit ensuring that the outer flex pipe overlaps
the collar by at
least 35mm. Fasten with the 3 screws.
5.
Repeat steps to secure the other end of the flex adapter using the flex kit.
6.
See Vertical Vent installation instructions or horizontal power
flue
instal-
lation instructions for installation of the complete vent system.
Note:
If an offset is necessary in the attic or floor joists it is important to
sup
-port the vent pipe every
914mm
to avoid excessive stress and
sagging of the vent pipe. Wall straps are provided (3 in total) for this
purpose.
All round/plumbers strapping may also be used if further supports are
required.
VERTICAL FLUE EXTENSION KIT (APPROVED MODELS)
HORIZONTAL POWER VENT KIT (CV72EPV, CB72EPV, CB40EPV, CV40EPV, & CC40EPV ONLY)
(PART # 946-756)
6m
Flex
P
ipe Extension
3 wall straps
flex adaptor
10
2
mm inner pip
e
1
68
mm
outer
flex pipe
6m
10 spring spacers
Note:
The flex
adaptor which is included with this
kit is only required when joining two of the
946-756
flue extension kits to a maximum of
12m
.
If only 1-946-756
6m
kit is used the flex
adaptor is not required.
1
VERTICAL FLUE EXTENSION KIT
HORIZONTAL POWER FLUE KIT (PART # 946-756)
919-698
919-698
06.12.18
06.12.18
60
Ceiling firestop
60
-1/4
Ceiling firestop
Diagram 1
Diagram 1
Diagram 1a
Diagram 1a
Enclosure
Ceiling firestop
Flashing
Termination Cap
Storm Collar
Roof support
Ceiling firestop
Enclosure
Ceiling firestop
Flashing
Termination Cap
Storm Collar
Roof support
Ceiling firestop
Firestop spacer to prevent
debris from falling into the ceiling
firestop
is too high for the application.
CEILING FIRESTOP/FIRESTOP SPACER
( PART # 946-757)
Used in conjunction with the 946-7
68
Vertical flex kit and 946-756 kit Vertical
flex extension kit/Horizontal power
flue
kit.
A ceiling firestop/firestop spacer
is to
be installed
in accordance with
local building codes
. To install the ceiling firestop/firestop spacer in a flat
ceiling or floor joist cut a
260mm
square hole. Frame the hole as show
n
in
Diagram 1 and install the ceiling firestop. Slide the top attic insulation
spacer onto the top of the attic insulation shield/firestop - See Diagram
1a. Secure with 4 screws/nails. If more than one is required, these
can be purchased separately.
Note:
The ceiling firestop/firestop spacer may be cut down to size if this shield
CEILING FIRESTOP/FIRESTOP SPACER
( PART # 946-757)
Used in conjunction with the 946-755 Vertical flex kit and 946-756 kit Vertical
flex extension kit/Horizontal power vent kit.
Firestop spacer to prevent
debris from falling into the ceiling
firestop
A ceiling firestop/firestop spacer must be installed when passing through
each floor or ceiling level. To install the ceiling firestop/firestop spacer in
a flat ceiling or floor joist cut a 10- ¼ inch square hole. Frame the hole as
show in Diagram 1 and install the ceiling firestop. Slide the top attic insula-
tion spacer onto the top of the attic insulation shield/firestop - See Diagram
1a. Secure with 4 screws/nails. If more than one is required, these can be
purchased separately.
Note:
The ceiling firestop/firestop spacer may be cut down to size if this shield
is too high for the application.
1
1
CEILING FIRESTOP / FIRESTOP SPACER (PART 946-757)
260mm square
hole
installation