background image

Содержание DB7*0 Series

Страница 1: ......

Страница 2: ......

Страница 3: ...roblems by creating a mechanical draught on chimneys with circular core and a maximum internal diameter of ø220 mm The Draftbooster is designed to withstand high temperatures associated with wood burning at a max temperature of 250 C and tolerates continuous operation on stoves and closed inserts The Draftbooster must always be on during start up lighting the fire and during refueling When the ope...

Страница 4: ... Impedance protected Yes Max temperature during opera tion C 250 Max temperature at standstill C 250 4 4 1 Precautions 1 Ensure sufficient supply of fresh air in the room where the stove is placed 2 Ensure firm support of the Draftbooster 3 Appropriate precautions must be taken in order to guarantee safe use of heat sources Requirements of supply air Required supply of fresh air must comply with l...

Страница 5: ...4 5 Installation 4 5 1 Assembly parts 1 4 x 2 4 x 3 4 x 4 4 x 5 1 x 6 2 x 7 1 x 8 1 x 9 1 x 10 4 x 11 1 x 12 1 x Be aware of sharp and pointy parts 3120034 DB7 DK SE NO UK DE 32 UK ...

Страница 6: ...ange adjust the flange legs to fitting the inner diameter of your chimney and fix the legs in this position The example below shows the setting for an inside chimney diameter of ø150 mm The legs must be fastened permanently in the adequate position with the 4 self tapping screws 4 4 4 4 150 180 200 220 3120034 DB7 DK SE NO UK DE UK 33 ...

Страница 7: ...4 5 4 Installing the bottom flange and wire on the Draftbooster 3 4 x 9 6 3120034 DB7 DK SE NO UK DE 34 UK ...

Страница 8: ... steel wire must always be securely fastened both to the Draftbooster and to the chimney Wrap the wire around the chimney and through the wire lock Tighten the wire in a downward direction and tighten the wire lock The wire must be tight to secure that the Draftbooster stays on the chimney but not so tight that it makes the Draftbooster tilt 7 3120034 DB7 DK SE NO UK DE UK 35 ...

Страница 9: ...e Draftbooster and to the chimney Begin by attaching the wire bracket to the chimney tighten the loop and clamp down the wire lock The wire is tightend in a downward direction enough to secure that the Draftbooster stays on the chimney but not so tight that it makes the Draftbooster tilt 8 6 5 3120034 DB7 DK SE NO UK DE 36 UK ...

Страница 10: ... the fire Strike a match inside the stove and keep it there noting if the smoke from the match is being drawn towards the top of the stove and out of the chimney 4 Listen carefully as well You should be able to hear the blade of the Draftbooster revolving 5 Light the fire and make sure that no smoke is escaping from the stove 6 Close the doors Is smoke escaping from the closed stove Close the air ...

Страница 11: ...rainage holes The manufacturer cannot be held responsible for water penetration into the chimney 4 8 2 Troubleshooting Observation Problem Solution No power supply to the Draftbooster The switch is off Poor electrical connections Check the switch Check and remedy the problem The power supply to the Draftbooster is on but it s not working Poor electrical connections Worn out battery in the remote c...

Страница 12: ...attas av denna deklaration överensstämmer m ota tämä selvitys koskee on seuraavien standardien mukainen sem eru meðtalin i staðfestingu Pessari eru i fullu samræmi við eftirtalda staðla sono stati fabbricati in conformità con le norme degli standard seguenti EN60335 1 EN60335 2 80 DS EN ISO 12100 2012 i h t bestemmelser i direktiv in accordance with entsprechen gemäß den Bestimmungen der folgenden...

Страница 13: ...www draft booster com ...

Отзывы: