6-1
Redline Communications Inc. Confidential and Proprietary
6
Self-Install End User
Troubleshooting
Troubleshooting Self-Install
The RedMAX self-install solution requires the inter-operational functionality between
various system components. Incorrect configuration of any one of these components will
result in problems.
Before beginning the troubleshooting procedures listed here, you must ensure that you
have established wireless connectivity between the subscriber unit and the sector
controller. as outlined in “Troubleshooting Device Management Issues” on page 5-13. The
sector controller must also be performing according to your baseline values. See
“Establishing and Recording the Baseline Configuration” on page 2-15.
Basic troubleshooting for the subscriber unit is provided in Appendix , “Self-Install End
User Troubleshooting”.
Note
RMS interoperability issues are addressed in the RMS-specific Redline
Management Suite Administration and Maintenance Guide.
No Data Connectivity
The following sections describe the possible cause of a loss of connectivity between the
subscriber unit and the sector controller.
Enabling Default Uplink Service Flow
The default downlink service flow is always enabled, but the default uplink service flow is
disabled by default in RedMAX 2.0 and later. You can enable the default uplink service flow
as follows:
Step 1
Login to the CLI as outlined in “Connecting to the Sector Controller Command Line
Interface” on page 2-5.