Replacing the Indoor Unit of the AN100U/UX
Note
This procedure is service impacting and should only be performed during a
scheduled maintenance window.
Step 1
If possible, perform a configuration backup from the disabled device. Refer to the RedMAX
AN100U/UX Base Station User Guide for detailed instructions.
Step 2
Power off the RPS and the disabled device.
Step 3
Unplug the primary power cable from the supply and then from the disabled device.
Step 4
Remove the device from the mounting rack, if applicable.
Step 5
Install the replacement device in the rack and connect the power cable from the RPS.
Step 6
Connect the primary power cable and then connect the other end to the power supply.
Step 7
If the device does not power up automatically, then turn it on.
Step 8
Verify the successful restart and correct operation. Review the event log to ensure the
correct radio type is listed.
Step 9
Verify that the software version of the new device is the same or higher than the disabled
device.
Step 10 Restore the configuration of the disabled device. Refer to the RedMAX AN100U/UX Base
Station User Guide for detailed instructions.
Step 11 Log into the Web client and navigate to Monitoring > Status. Review the Status page to
verify that the air interface is enabled and to ensure the sector controller is operating
normally.
Step 12 Navigate to Monitoring > SS Info and verify any subscriber units are registered as
expected.
Step 13 Verify the wireless interface configuration: Interface Configuration > Wireless Interface.
The subscriber units should re-connected as soon as the sector controller is powered up.
You can verify the other operating parameters as required.