Redline Communications Inc. Confidential and Proprietary
DSA Failure: [SS Id], SFID [x]
(too many)
[nn]DSA (Dynamic Service Addition)
failed because there are too many
provisioned service flows for this
subscriber unit.
Try to reduce the number of active service flows
for the subscriber unit, identified by [SS ID].
DSC Failure: SFID [x] (retries)
{nn]
DSC (Dynamic Service Change) failed
because of message retransmissions.
Information only. There is no action required.
DSC Failure: [SS Id], SFID [x]
(RuleIndex not found)
DSC (Dynamic Service Change)
because a classifier for a downlink
service flow cannot be changed
because the classification rule index
cannot be found.
Contact [email protected].
DSC Failure: [SS Id], SFID [x]
(rsp)
DSC (Dynamic Service Change) failed
because the subscriber unit (SS ID)
sends an unsuccessful response code
(rsp).
Information only. There is no action required.
FPC: [SS Id] (power: x)
The sector controller has sent a Fast
Power Control message to the
subscriber unit (SS ID).
The power (x) is a signed integer that
represents quarters of a dBm.
This is not an alarm condition.
Information only. There is no action required.
SBC Failure: [SS Id]
The subscriber unit (SS ID) has sent
an SS Basic Capabilities (SBC)
request before the initial ranging was
complete.
SS Basic Capabilities (SBC) negotiation is a
protocol stage during the network entry process
described by the 802.16 standard.
SS Deregistered: (corrRetries
[t], [f])
A subscriber unit (SS ID) is
deregistered due to a maintenance
ranging failure.
The correction retries counter has
been reached.
The time offset [t] and the frequency
offset [f] are reported.
After subscriber unit de-registration due to
maintenance ranging failure the subscriber unit
will re-entry the network.
This event may be the result of the subscriber
unit link quality being affected by multipath
interference.
SS Deregistered: [SS Id]
(DREG-Req)
The user forces a subscriber unit (SS
ID) to deregister.
Information only. There is no action required.
SS Deregistered: [SS Id]
(Re-Ranging)
A registered subscriber unit (SS ID)
attempts initial ranging because it has
lost the link and is restarting the
registration process from the
beginning.
Information only. There is no action required.
SS Deregistered: [SS Id]
(rngRetries)
A subscriber unit (SS ID) is
deregistered because the sector
controller did not receive OFDM signal
from that subscriber unit.
Information only. There is no required action.
This event may be logged if the path loss
(attenuation) is too high or strong interference is
present.
Table B-1
AN100U/UX Event Log Messages (continued)
Message
Description
Comment