B-9
Appendix B AN100U/UX Event Log Messages
Redline Communications Inc. Confidential and Proprietary
SS Reset Command: [SS Id].
The user has reset the SS.
Information only. There is no action required.
SS Reset: [SS Id]
The sector controller sent a reset
command because the default
(downlink or uplink) service flow
creation failed.
Information only. There is no required action.
SS: [SS Id] (Re-Init Ranging)
A subscriber unit was re-attempting
initial ranging while it was in the
middle of the registration process.
The subscriber unit (SS ID) has lost
the link and starts the registration
process from the beginning.
Information only. There is no required action.
Timing anomalies reported by
SS: [SS ID]
The subscriber unit (SS ID) cannot
apply the timing corrections sent by
the sector controller.
Information only. There is no required action.
If this event occurs continuously, then contact
[email protected].
NTP-Related Messages
NTP Client: Invalid address
The IP address of SNTP server cannot
be resolved
Verify that you have specified the proper address
for your SNTP server.
NTP Client: Server Unsync
The received timestamp is 0, or the
SNTP server suggests it is not
synchronized
Problems with excessive network congestion or
delay can cause synchronization to fail.
Allow the AN100U/UX to refresh the time again.
If the problem persists, verify the network
connectivity between the AN100U/UX and the
SNTP server
NTP Client: Timeout
The SNTP server does not reply to
SNTP requests
Verify that the SNTP service is started on your
server, and that there are no firewalls interfering
with communication between the AN100U/UX
and the time server.
NTP Client: Version
unsupported
SNTP server version number is
greater than 3.
SNTP versions greater than 3 are only
used for IPv6 networks. The
AN100U/UX currently, only supports
IPv4.
Verify the version number of your SNTP server
and downgrade the application as required.
ODU-Related Messages
Cable Compensation Ok.
Value = [v]
The attenuation of the IF cable is
within normal operating parameters.
Information only. There is no required action.
The cable compensation-related messages are
not displayed when an HTB is used.
Table B-1
AN100U/UX Event Log Messages (continued)
Message
Description
Comment