Appendix D Synchronization Event Log Messages
D-3
Redline Communications Inc. Confidential and Proprietary
Backup Master
(after rebooting)
Master or GPS must be connected.
Waiting...
No connection between the GPS and the Master with GPS.
The Master with GPS is offline.
Check the Master with GPS and
ensure it is online and that the GPS
is connected to the Sync In port of
the Master with GPS.
Ensure that the Master with GPS is
also connected to the Sync In port
of the Backup Master.
Slave
Synchronization Signal not Detected.
Waiting...
Master and Backup Master are offline, after rebooting.
Check the Master with GPS and the
Backup Master and ensure they are
online and that the GPS is
connected to the Sync Out port.
Master
Other Master Detected. Waiting...
More than one sector controller has been configured as the
Master with GPS.
Change the configuration of one
sector controller so that you have
only one device configured as the
Master with GPS.
Backup Master
Other Backup Detected. Waiting...
More than one sector controller has been configured as the
Backup Master
Change the configuration of one
sector controller so that you have
only one device configured as the
Backup Master
Master
Synchronization Signal not Detected.
Waiting...
No Connection between the Master with GPS and the GPS Clock Check the Master with GPS and
ensure it is online and that the GPS
is connected to the Sync In port.
Check that the Master and Backup
Master are synchronized.
Master
GPS is not Detected
No Connection between the GPS and the Master with GPS.
No event log message is displayed by the Backup Master or the
Slave devices.
Check the Master with GPS and
ensure it is online and that the GPS
is connected to the Sync In port.
Table D-1
AN100U/UX Synchronization Event Log Messages (continued)
Message Reported
By
Event Log Message
(Logged starting from bottom to top)
Probable Cause
Recommended Troubleshooting