5-13
Chapter 5 AN100U/UX Troubleshooting
Redline Communications Inc. Confidential and Proprietary
Step 5
Ensure the subscriber unit is configured for remote management. See Table 5-3 for details
of the available options
Step 6
Enter Ctrl-Z to return to the root mode.
Refer to the RedMAX Outdoor Wireless Access Subscriber Modem (SUO) User Guide for
detailed information on using the CLI.
Troubleshooting Device Management Issues
Establishing a connection with the management interface of the RedMAX system is
essential to network productivity. Management of the sector controller can be done
primarily via the HTTP GUI (web client). Device connectivity is also available via Telnet,
Serial port, or SNMP. For larger networks, you should consider the Redline Management
Suite element management application.
Configuration of the subscriber unit is available only via a Telnet session.
Sector Controller Serial Communication Issues
As indicated previously, the most common problem is that you are using a straight-through
cable and require a cross-over connection.
Table 5-3
Speed/Duplex Settings for the SUO Management Port
Command
Options
ethernet
Use this setting to modify the Ethernet port auto-negotiation, link speed, and duplex
settings.
AutoNegEnabled <value>
Where a value of 0 corresponds to disabled and a value of 1 corresponds to
enabled.
LinkSpeed <value>
Where a value of 0 corresponds to 10Mbps and a value of 1 corresponds to
100Mbps.
LinkDuplex <value>
Where a value of 0 corresponds to Half Duplex and a value of 1 corresponds to
Full Duplex.
managedSS
The managedSS command allows you to configure the subscriber unit for
independent operation, or enable management using the Redline Management
Suite (RMS). The managedSS parameter is controlled from root mode.
managed SS <value>
Where a value of 0 corresponds to Disable remote management and a value of 1
corresponds to Enable remote management.